High Strength Electric Gate Valve for Hopper Unloading Device

Product Details
Customization: Available
Media: Granule / Dust / Particle
Temperature: Ordinary Temperature
Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Experienced Team
The supplier has 6 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
to see all verified strength labels (21)
  • High Strength Electric Gate Valve for Hopper Unloading Device
  • High Strength Electric Gate Valve for Hopper Unloading Device
  • High Strength Electric Gate Valve for Hopper Unloading Device
  • High Strength Electric Gate Valve for Hopper Unloading Device
  • High Strength Electric Gate Valve for Hopper Unloading Device
  • High Strength Electric Gate Valve for Hopper Unloading Device
Find Similar Products

Basic Info.

Material
Cast Iron
Connection Form
Flange
Pressure
Low Pressure
Actuator
Electric/ Pneumatic / Manual
Seal Surface
Parallel Gate Valve
Thread Position of Valve Rod
Inside Gate Valve
Usage
Flow Control
Standard
DIN
Application
Industrial Usage
Granulary
50mm
Size
150-1000mm
Flange
Circle or Square Shape
Frame Material
Mild Steel or Stainless Steel
Transport Package
Wooden Case
Specification
small
Trademark
JY
Origin
China
HS Code
8481804090
Production Capacity
5000sets/Year

Product Description

High Strength Electric Gate Valve for Hopper Unloading Device

Gate Valve  

High Strength Electric Gate Valve for Hopper Unloading Device
There are three types of plug-in valves: manual plug-in valves, electric plug-in valves, and pneumatic plug-in valves. Manual plug-in valves are also called manual screw gate valves. They are usually used in un-loaders.
Manual plug-in valve, also known as manual knife-type gate valve, knife-shaped gate valve is a kind of valve that the gate and the valve seat are always in close contact and seal. The principle is that the gate board has a diameter-sized round opening and is opened by the gate. Closing makes the round hole on the ram plate completely separate from and coincide with the diameter
Size range: ∅200x200-930x930

High Strength Electric Gate Valve for Hopper Unloading Device
 
Conditions of use
Applicable temperature: -10~+200°C
Connection flange: GB/T9113, JB/T79; Body material: WCB, Q235A, 304, 316, 304L, 316L; Seal type: Hard seal, soft seal
Accessories: mounting flange, solenoid valve, air filter, travel switch
Air source pressure: 0.4~0.6MPa
Use and Advantage:

Widely used in metallurgy, mining, building materials, food, manual spiral gate diameter and un-loader feed port matching; there are two kinds of square and round.
The advantage of this valve is that there is no groove in the valve body, and the medium does not block and block, and it has full-diameter flow characteristics, which is suitable for use in the pipeline of powder and granular media.
The plug door seal structure can be divided into soft seal and hard seal structure. With features such as good workmanship and compact structure, the sealed valve seat is designed as a movable structure and has the functions of anti-wear and automatic compensation, and thus has a longer life. During the closing and opening process of the inserting plate door, the valve seat and the gate plate are always in close contact with each other, so that the valve opening and closing force is stable and has the characteristics of cutting off the medium.
Configure the hand wheel to operate the hand wheel directly to open and close the valve.
High Strength Electric Gate Valve for Hopper Unloading Device
C B A C1*C1 B1 A1*A1 H1 H N-∅
∅200 260 ∅300 200*200 250 300*300 200 200 8-∅11
∅220 280 ∅320 220*220 270 320*320 200 200 8-∅11
∅240 300 ∅340 240*240 290 340*340 200 200 8-∅13
∅260 320 ∅360 260*260 310 360*360 200 200 8-∅13
∅280 340 ∅380 280*280 330 380*380 200 200 8-∅17
∅300 360 ∅400 300*300 350 400*400 200 200 8-∅17
∅320 380 ∅420 320*320 370 420*420 200 200 8-∅17
∅340 400 ∅440 340*340 390 440*440 200 200 8-∅17
∅400 460 ∅500 400*400 450 500*500 220 220 8-∅17
∅440 500 ∅540 440*440 495 550*550 220 220 12-∅17
∅500 560 ∅610 500*500 555 610*610 220 220 12-∅17
∅540 600 ∅650 540*540 600 650*650 220 220 12-∅17
∅600 660 ∅720 600*600 660 720*720 240 240 12-∅20
∅650 720 ∅770 650*650 720 770*770 240 240 12-∅20
∅700 770 ∅820 700*700 765 820*820 240 240 12-∅20
∅750 820 ∅870 750*750 825 870*870 240 240 12-∅20
∅800 870 ∅930 800*800 870 930*930 270 270 12-∅20
High Strength Electric Gate Valve for Hopper Unloading Device
High Strength Electric Gate Valve for Hopper Unloading Device


Installation:
1.Before installation, check the inside of the valve chamber and the sealing surface, and do not allow any dirt or sand particles to adhere;
2. The bolts at each connecting point require uniform tightening;
3. Check that the packing area is pressed tightly to ensure not only the packing's tightness, but also the flap's opening flexibility;
4. Before the user installs the valve, the model of the valve must be calibrated, the connection size and the direction of the medium should be observed to ensure consistency with the valve requirements.
5. The user must reserve the necessary space for valve actuation when installing the valve.
6. The wiring of the driving device must be carried out according to the wiring diagram;
7. The flapper valve must be maintained regularly and must not be crushed and squeezed so as not to affect the seal.
High Strength Electric Gate Valve for Hopper Unloading Device
High Strength Electric Gate Valve for Hopper Unloading Device

High Strength Electric Gate Valve for Hopper Unloading Device
High Strength Electric Gate Valve for Hopper Unloading Device
High Strength Electric Gate Valve for Hopper Unloading Device

 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now