Pre-Filter Waste Air Treatment Industrial Cyclone Filter

Product Details
Customization: Available
Certification: CE, ISO
Installation
Method:
Horizontal
Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Experienced Team
The supplier has 6 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
to see all verified strength labels (21)
  • Pre-Filter Waste Air Treatment Industrial Cyclone Filter
  • Pre-Filter Waste Air Treatment Industrial Cyclone Filter
  • Pre-Filter Waste Air Treatment Industrial Cyclone Filter
  • Pre-Filter Waste Air Treatment Industrial Cyclone Filter
  • Pre-Filter Waste Air Treatment Industrial Cyclone Filter
  • Pre-Filter Waste Air Treatment Industrial Cyclone Filter
Find Similar Products

Basic Info.

Model NO.
JY-2000
Dust Collecting Method
Dry
Type
Cyclone Dust Collector
Efficiency
85-99%
Material
Carbon Steel
Airflow
1000-13500cfm
Diameter
1000-4100mm
Transport Package
Steel Frame
Specification
large
Trademark
JY
Origin
China
HS Code
8421392990
Production Capacity
3000sets/Year

Product Description

Pre-Filter Waste Air Treatment Industrial Cyclone Filter
           Pre-Filter Waste Air Treatment Industrial Cyclone Filter


Pre-Filter Waste Air Treatment Industrial Cyclone Filter
The XLP type cyclone dust collector is a high-efficiency cyclone dust collector with a bypass channel on the outside of the cyclone cylinder body. It can make a part of the gas containing more dust near the inner wall of the cylinder pass through the bypass into the lower part of the cyclone barrel to reduce the dust from being discharged, especially for dusts larger than 5μm, has a higher dust removal efficiency. It is used to remove dense non-fibrous and cohesive dust from industrial exhaust gases. It can effectively separate tobacco ash, talcum powder, quartz powder, limestone powder, slag cement, cement raw material, etc. It has the characteristics of simple structure, convenient operation, high temperature resistance, low resistance and high dust removal efficiency. It is suitable for mining, metallurgy and fire-resistant Gas purification in industrial sectors such as materials, coal, chemicals, building materials and electricity.
 
Pre-Filter Waste Air Treatment Industrial Cyclone Filter
 
Features:
 
After the dust-laden gas enters the tangential direction from the inlet, the gas is divided into the upper and the lower while the gas is rotating. At the same time, the dust forms a strong vortex at the bottom of the exhaust, that is, the boundary between the two vortexes. The finer and lighter dust particles are carried upwards by the upper vortex airflow, and a strongly rotating ash ring is formed under the top cover, resulting in the accumulation of dust particles, which are led out from the upper hole of the special bypass separation chamber and separated by the bypass. The spiral groove in the lower part of the chamber is tangentially introduced into the lower part of the dust collector cylinder from the air inlet of the dust collector outer wall to merge with the internal air flow, and the dust is separated and dropped into the ash bucket. The other part of the heavier dust particles is driven by the downward vortex, and the dust is separated and entered into the ash hopper along a similar process of the upper vortex flow in the lower part of the dust collector.
 
XLP type bypass cyclone dust collector is lower than the inlet position of the general cyclone dust collector, so that there is enough space on the top of the dust collector to form an upper vortex and form a dust ring, leading from the bypass separation chamber to the cone part, which is harmful to The secondary flow of dust removal efficiency turns into an upper vortex flow with dust accumulation. The bypass separation chamber is designed as a spiral so that the incoming dust-containing airflow cuts into the cone tangentially to avoid disturbing the airflow inside the cone and prevent dusting again.
 
1, according to the XLP type bypass cyclone dust collector air way classification. Type X (horizontal air outlet, suction-type dust remover is located on the suction side of the fan and has an outlet volute), generally used for negative pressure operation; Y type (upper air outlet, press-in dust collector is located on the press-in side of the fan), Generally used for positive pressure or negative pressure operation.
 
2, according to the direction of convolution can be divided into right-swirling S-type and left-spin N-type two, two types of dust collector has four types of combination (XN, XS, YN, YS type).
 
3, according to the spiral bypass separation chamber classification. XLP/A has a semi-helical shape and a double cone shape; XLP/B has a full spiral shape, a single cone with a small cone angle, and a long cone. Tests have shown that under the same conditions, Type A efficiency is higher than Type B, while Type A resistance is greater than Type B, and Type B is simpler and of lower quality than Type A.

Pre-Filter Waste Air Treatment Industrial Cyclone Filter

Mpdel XLP-A:
 
Model number Air flow
m3/h
Resistance kg/m2 Efficiency
%
Dimension(L×W×H)mm Weight
kg
X Y X Y X Y
XLP/A-3.0 750-1060 45-90 39-79 85-99 406×390×6125 460×390×1380 57 43
XLP/A-4.2 1460-2060 556×545×2177 556×545×1880 99 80
XLP/A-5.2 2280-3230 711×700×2701 771×700×2701 165 128
XLP/A-7.0 4020-5700 911×910×3489 911×910×3040 265 213
XLP/A-8.2 5500-7790 1071×1605×4050 1071×1605×3540 364 293
XLP/A-9.4 7520-10650 1226×1222×4616 1226×1222×4050 473 384
XLP/A-10.6 9520-13500 1376×1337×5157 1376×1337×4545 631 483

Model XLP-B:
 
Model Inlet Wind Speed(m/s) Airflow(m3/h) Resistance(kg/m2) Efficiency  % Dimension(Length*Width*Height) Weight(kg)
X Y X Y
XLP/B~3.0 12-27 650-1050 30-90 27-75 85-99 438*381*1606 439*381*1360 66
XLP/B~4.2 1280-2138 603*534*2172 630*534*1375 108
XLP/B~5.4 2090-3480 772*685*2764 772*685*2395 170
XLP/B~7.0 3650-6080 994*889*3529 994*889*3089 283
XLP/B~8.2 5030-8380 1167*1040*4110 1176*1040*3600 374
XLP/B~9.4 6550-10620 1332*1094*4671 1332*1194*4110 477
XLP/B~10.6 8370-13980 1495*1345*5232 1495*1345*4621 578

Pre-Filter Waste Air Treatment Industrial Cyclone Filter
Pre-Filter Waste Air Treatment Industrial Cyclone Filter


Pre-Filter Waste Air Treatment Industrial Cyclone Filter

Pre-Filter Waste Air Treatment Industrial Cyclone Filter
Pre-Filter Waste Air Treatment Industrial Cyclone Filter
Pre-Filter Waste Air Treatment Industrial Cyclone Filter
Pre-Filter Waste Air Treatment Industrial Cyclone Filter
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier